Cold Formed Z Purlin

Cold Formed Z Purlin
Details:
Standards: EN 10346 / ASTM A653/A653M.
Grades: S250GD / S280GD / S350GD.
Material: Galvanized structural steel.
Process: Cold roll forming.
Delivery: As-formed; punched or unpunched.
Dimensions: Custom section sizes and lengths.
Inspection: Dimensional checks; MTC on request.
Applications: Roof purlins and wall girts.
Send Inquiry
Description
Send Inquiry

Xi'an Dongmeng Group Co., Ltd. is one of the most reliable manufacturers and suppliers of cold formed z purlin in China, also supports customized service. With abundant experience, we warmly welcome you to wholesale cheap products in stock here and get free sample from our factory. For price consultation, contact us.

 

Cold Formed Z Purlin
Cold Formed Z Purlin

Galvanized Z Sections for Steel Roofs and Secondary Framing

Xi'an Dongmeng Group Co., Ltd. supplies cold formed Z purlins for industrial roofs, warehouse buildings and secondary steel framing. Formed from steel strip into a Z-shaped section, these members support roof sheeting or suitable wall cladding systems. Orders can be reviewed against approved drawings covering structural grade, coating, section geometry, base metal thickness, length and connection holes.

For engineered multi-bay roofs, compatible Z sections can be lapped at supports to create a continuous purlin system. The required lap, connections and restraint depend on the selected structural design.

Custom Lengths • Drawing-Based Profiles • Punched or Unpunched Options

Request a Quote | Send Your Drawing | Request Material Documents

 

What Is a Cold Formed Z Purlin?

 

A cold formed Z purlin is a secondary structural member manufactured by forming sheet or strip at ambient temperature. Its two flanges extend to opposite sides of the web. Lipped profiles also have folded flange edges that contribute to section stability.

In many lappable systems, the flange widths differ so adjacent members can nest at the support. Lip dimensions, bend radii and orientation must also match the connection design. A Z-shaped profile alone does not establish that two members can be lapped. stramit.com.au

Roof purlins transfer loads from the roof covering to rafters or frames. Similar profiles may serve as wall girts when the wall system is designed for their geometry and restraint conditions.

Why Specify Z Purlins for Your Project?

Efficient Secondary Framing

Thin-walled, formed sections distribute material through the web, flanges and lips. They can provide an economical framing solution when section size, grade and restraint are selected for the project.

Lapped Continuity for Multi-Bay Roofs

Compatible Z sections can overlap at supports. An engineered lap can improve system capacity and stiffness, with the benefit determined by the connection and span arrangement. lysaght.com

Coating Matched to the Environment

Galvanized feedstock provides zinc protection before forming. Buyers can specify the coating designation alongside the steel grade and exposure conditions.

Processing Matched to Installation Drawings

Cut lengths and approved hole patterns help coordinate purlins with frame cleats, lap connections and bridging. Unpunched members can also be requested.

Clear Procurement and Traceability

A defined order links each section to its drawing, material specification and inspection requirements, helping buyers compare technically consistent quotations.

Z Purlin Specifications and Ordering Parameters

The following table is an RFQ guide. It is not a stock list or a guarantee that every combination is available.

Parameter Specification / Ordering Requirement
Product form Cold formed Z section; lipped geometry as specified
Section depth, h Market reference: 100–400 mm, approximately 3.94–15.75 in
Base metal thickness, t Market reference: 1.2–3.0 mm, approximately 0.047–0.118 in
Flange widths, b1 / b2 Specify each flange separately
Lip dimensions, c1 / c2 Specify lengths, angles and orientation
Internal bend radius, r According to the approved drawing and forming requirements
Member length, L Cut length and tolerance to be agreed; transport limits also apply
Steel grade Specify the material standard, grade and applicable class
Coating State coating type, designation and governing standard
Holes / slots Unpunched or drawing-based pattern
Section tolerances Applicable agreed standard and drawing-specific requirements
Unit mass Confirm the calculation or measurement basis, including coating mass

Example RFQ description - illustrative only:

Lipped Z purlin, h = 200 mm, b1 = 70 mm, b2 = 65 mm, c1 = c2 = 20 mm, BMT = 2.0 mm, L = 6,000 mm, S350GD to EN 10346, Z275 coating, unpunched, quantity according to the attached member schedule.

Include bend radii, lip orientation and dimensional tolerances on the drawing before production approval.

Base Metal Thickness vs Total Coated Thickness

BMT means the thickness of the steel substrate, excluding the metallic coating. Total coated thickness includes the coating on both surfaces.

State whether the ordered thickness is nominal BMT or a minimum required BMT, and identify its permitted tolerance. A reading taken on a coated surface needs the correct measurement basis before comparison with the order.

Send your section drawing and member schedule for a quotation based on the same dimensional and thickness requirements.

Material Grades and Applicable Standards

Material, dimensional and structural design standards perform different jobs. Select the required route in the purchase specification.

Specification Area Reference What to Confirm
Galvanized structural feedstock EN 10346 Structural grade, coating designation and material certificate
Galvanized structural feedstock ASTM A653/A653M Structural steel designation, grade/class and coating designation
Metallic-coated structural feedstock AS 1397 Steel grade, coating class and thickness requirements
Formed-section geometry EN 10162, where applicable and agreed Cross-section and dimensional tolerances
Structural design ANSI/SDI AISI S100, EN 1993-1-3 or AS/NZS 4600 Locally adopted/project-specified edition and system design requirements

ASTM A653/A653M addresses coated steel sheet and coil. It does not independently establish the load capacity of a finished Z purlin installation. A material certificate also does not replace the structural design of spans, connections and restraint.

Reference Mechanical Properties

The following values refer to longitudinal tensile properties of EN 10346 coated structural sheet in the 1.2–3.0 mm thickness band. They are material reference limits, not finished-purlin load ratings.

Grade Minimum Yield Strength Minimum Tensile Strength
S250GD 250 MPa 330 MPa
S280GD 280 MPa 360 MPa
S350GD 350 MPa 420 MPa

Verify complete requirements and actual batch results against the applicable standard and certificate. Grades under different standards require technical review before substitution. A forming-grade designation such as DX51D should not replace a specified structural grade without verification of the required properties.

Galvanized Coating Selection

 

Specify the coating as part of the material order. Under EN 10346, Z275 denotes a minimum coating mass of 275 g/m² total across both surfaces, assessed using the prescribed test requirements. It does not mean 275 g/m² on each surface or a coating thickness of 275 microns. industry.arcelormittal.com

A suitable coating depends on humidity, condensation, atmospheric exposure, chemical contact and maintenance access. Agricultural buildings and locations exposed to persistent moisture may need additional review.

When comparing quotations, confirm the standard and coating designation rather than accepting "galvanized" as a complete specification. Cut edges, holes and coating damage should be addressed by the project's agreed protection and repair requirements.

Pre-galvanized strip forming and galvanizing after fabrication are different process routes. If post-fabrication galvanizing is requested, its feasibility, coating standard and effect on the finished profile need separate review.

C Purlin vs Z Purlin

Selection Point C Purlin Z Purlin
Flange direction Both flanges on the same side of the web Flanges on opposite sides
Typical detailing Single spans, eaves and compact connections Single spans and engineered multi-bay roofs
Continuity Unlapped or specially connected systems Direct lapping possible with compatible profiles
Connection requirements Cleats, sleeves or other designed details Lap geometry, fasteners, cleats and restraint
Selection basis Loads, geometry, connections and restraint Loads, geometry, connections and restraint

A Z purlin is not automatically stronger than a C purlin. Compare the complete systems under the same loading, span and support conditions.

How to Select the Correct Z Purlin

Start with the building design and connection details. Section depth alone is insufficient to select a member.

Design Input Why It Matters
Span and bay arrangement Determines the structural system and moment distribution
Purlin spacing Determines the roof area contributing load to each member
Downward loads and wind uplift Both loading directions require verification
Roof pitch and sheeting attachment Affect loading and available restraint
Lap length and fasteners Define force transfer through the support connection
Bridging and anti-sag system Provide specified member restraint
Grade, BMT and complete section geometry Affect strength, stability and stiffness
Deflection criteria and support bearing Address serviceability and local support behavior

Use load tables only when their profile, material and system assumptions match the supplied installation. Higher yield strength does not remove deflection or buckling checks. Any substituted section, hole pattern or lap arrangement requires review by the project's structural designer.

Manufacturing and Custom Processing

The normal roll-forming route includes feedstock verification, strip preparation, forming, cutting, any specified punching, and final inspection. The sequence of cutting and punching depends on the production arrangement.

Dongmeng Group can review the following requirements against drawings and production feasibility:

Requested Service Information Needed
Cut-to-length Member lengths, quantities and permitted variation
Punching / drilling Hole or slot dimensions, pitch, edge distances and orientation
Section customization Depth, flange and lip geometry, BMT and bend radii
Member identification Mark number, drawing revision and bundle grouping
Surface alternatives Coating specification and exposure conditions
Packing coordination Bundle size, lifting needs and unloading restrictions

Attach your approved section drawing and hole layout when requesting customized Z purlins.

Typical Applications

 

Application Typical Role Procurement Focus
Industrial warehouses Secondary roof framing Bay arrangement, roof loads and lap schedule
Workshops and factories Roof support Services loads, connections and restraint
Agricultural buildings Roof purlins and suitable wall girts Moisture, exposure and coating
Pre-engineered steel buildings Repeated secondary members Member marks, cut lengths and hole consistency

Compatibility with roofing or sandwich panels also depends on panel spans, fasteners and the designed connection system.

Quality Control and Material Documentation

Agree the inspection plan before placing the order. It can include the following checks and records:

Inspection Item Verification Focus
Feedstock identity Grade, coil/heat reference and material documents
Thickness and section geometry BMT basis, depth, flanges, lips and bend details
Length, straightness and twist Specified tolerances
Connection holes Diameter, position, pitch, orientation and burr condition
Coating and surface Coating evidence, surface damage and required checks
Final identification Member marks, quantities and packing-list correspondence

EN 10204 3.1 material certificates may be requested where supported by the material producer and agreed in the order. Identify whether a document covers the input coil or the supplied finished section. Dimensional inspection records provide separate evidence of finished-profile conformity.

Optional third-party inspection should be agreed before production or dispatch, including its scope and acceptance criteria.

Request the agreed document list and an available certificate sample with your enquiry.

Export Packing and Shipment Preparation

 

Packing requirements can include nested profiles where geometry permits, supported bundles, protective separators and strapping suitable for handling. Grouping members by length or installation mark can help organize unloading.

Bundle labels should identify the section, length, quantity and agreed material reference. Long members require a shipment plan that accounts for container or vehicle limits and handling access.

Keep profiles dry and appropriately supported during storage to reduce moisture-related coating damage and distortion. Packing method, bundle mass and dispatch timing are confirmed with the order.

 

Project Supply Support from Dongmeng Group

Dongmeng Group supports drawing-based sourcing of steel profiles and related building materials. For Z purlin enquiries, we review section requirements, the material route, processing details and shipment needs so the quotation can be compared with the project specification.

Related enquiries may cover C purlins, structural steel sections, galvanized products and steel building components. Confirm the scope of each order, including which accessories and inspection documents are included.

Frequently Asked Questions

1. What is the main advantage of a Z purlin?

Compatible Z profiles can be lapped at supports in an engineered multi-bay system. The structural benefit depends on lap geometry, fasteners, spans and restraint.

2. Can all Z purlins be overlapped?

No. Profiles must have compatible flanges, lips, radii and orientation. The overlap length and connection pattern must also match the approved design.

3. What sizes should I include in an enquiry?

Specify depth, both flange widths, both lips, BMT, bend radii and length. A designation such as "Z200" is manufacturer-specific and does not fully define the section.

4. Which steel grade should I choose?

Use the grade specified by the structural designer. S250GD, S280GD and S350GD are examples of EN coated structural grades. Other standards require their own grade and property checks.

5. Is galvanized thickness the same as BMT?

No. BMT excludes the metallic coating. State the thickness basis and tolerance so quotations and inspection readings are comparable.

6. Can I order Z purlins without holes?

Yes, unpunched profiles can be requested. If punching is required, send the hole layout with member orientation and dimensional requirements for feasibility review.

7. What zinc coating should I specify?

State the coating designation and governing standard, together with the exposure environment. The word "galvanized" alone does not define the required coating.

8. Can you provide a safe span or load capacity?

A capacity check needs the complete section, grade, BMT, span arrangement, connections, restraint, loading and applicable design code. A general product size is insufficient.

9. Are certificates and third-party inspection available?

Material documentation and optional independent inspection can be reviewed with the enquiry. Specify the certificate type, traceability and inspection scope before ordering.

10. What are the MOQ, lead time and price?

These depend on material availability, section geometry, lengths, quantity, processing and packing. Send your drawing, member schedule and destination for an order-specific quotation.

Request a Cold Formed Z Purlin Quote

For an initial quotation, send:

Section drawing: Depth, flanges, lips, BMT, radii and orientation.

Material specification: Standard, grade and coating designation.

Member schedule: Cut lengths and quantity for each mark.

Processing: Unpunched or an attached hole layout.

Delivery: Destination and required delivery date.

Add special tolerances, inspection documents, accessories and packing requirements where applicable.

Request a Quote | Send Your Drawing | Request Material Documents

Office Information

Contact Item Details
Phone +86 157 6921 4734
Email office@dongmjd.com
WhatsApp +86 157 6921 4734
Office Address Room 4107, Runfeng Building, Sanqiao New Street, Weiyang District, Xi'an City, Shaanxi Province, China

 

Hot Tags: cold formed z purlin, China cold formed z purlin manufacturers, suppliers, factory

Send Inquiry