Xi'an Dongmeng Group Co., Ltd. is one of the most reliable manufacturers and suppliers of steel h pile in China, also supports customized service. With abundant experience, we warmly welcome you to wholesale cheap products in stock here and get free sample from our factory. For price consultation, contact us.

Steel H Pile / HP Section
Hot-Rolled HP Sections for Driven Foundations
Xi'an Dongmeng Group Co., Ltd. supports project-based procurement of steel H piles and HP sections for foundation contractors, infrastructure projects and steel distributors. Specify your section designation, steel grade, pile lengths and documentation requirements to receive a quotation aligned with your project specification.
HP bearing piles are hot-rolled steel sections with wide parallel flanges and web and flange thicknesses that are equal or closely matched. Their open section is used in driven foundation systems and engineered soldier pile arrangements.
Request an H Pile Quote | Send Your Pile Schedule
What Is a Steel H Pile?
A steel H pile is a bearing pile with an H-shaped cross-section, typically used to transfer foundation loads through weaker ground to suitable bearing strata. Depending on the ground conditions and design, resistance may develop at the pile toe, along the shaft, or through both mechanisms.
The HP series is a dedicated bearing-pile section family. An ordinary H beam or W beam should not replace a specified HP section solely because it looks similar. Section geometry, material properties, driving conditions and connection details must satisfy the approved design.
Procurement Advantages
Defined section identity: Compare quotations for the same HP profile.
Grade-based purchasing: Specify material strength independently of section size.
Length planning: Separate initial pile lengths, extension pieces and splice requirements.
Drawing-based preparation: Review cutting, end preparation and connection work against approved drawings.
Documented delivery: Connect supplied material with the purchase specification through heat identification and inspection records.
Standards and Material Grades
Specify the section standard, material standard and required edition together. A dimensional standard alone does not define the steel grade.
| Procurement route | Dimensions / tolerances | Material specification | Ordering requirement |
|---|---|---|---|
| American HP sections | ASTM A6/A6M | ASTM A572/A572M Grade 50 is a common route | Complete HP designation, grade and standard edition |
| Other ASTM material routes | Applicable ASTM A6/A6M requirements | A572 Grades 55, 60 or 65; A992 or A709 where specified | Confirm section availability and project acceptance |
| European HP sections | EN 10365 dimensions; EN 10034 tolerances | EN 10025-2, including specified S355 grades | Complete grade, toughness requirement and delivery condition |
These standards represent different procurement routes; they do not establish automatic equivalence between profiles or grades.
Material Selection Notes
| Requirement | What the buyer should confirm |
|---|---|
| ASTM A572 Grade 50 | Minimum specified yield strength of 50 ksi [345 MPa], applicable product requirements and mill test results |
| Higher-strength ASTM grades | Engineering approval, section availability, welding requirements and supplementary tests |
| S355JR / S355J0 / S355J2 | Complete EN grade, thickness-dependent properties, impact requirements and delivery condition |
| Impact toughness | Test temperature, required energy, sampling and reporting |
| Cross-standard substitution | Chemistry, mechanical properties, toughness, dimensions and documentation |
Do not assume that an unspecified Charpy impact requirement is included in an ASTM A572 order. Additional toughness requirements should be agreed before purchasing.
Steel H Pile Dimensions and Weight
American HP Reference Sizes
Reference profiles from the Nucor-Yamato catalogue, March 2024 HP table. These are selection references, not confirmed stock.
| HP designation | Weight (lb/ft) | Approx. weight (kg/m)* | Depth d (in) | Flange width (in) | Web thickness (in) | Flange thickness (in) |
|---|---|---|---|---|---|---|
| HP8×36 | 36 | 53.6 | 8.0 | 8.155 | 0.445 | 0.445 |
| HP10×42 | 42 | 62.5 | 9.7 | 10.075 | 0.415 | 0.415 |
| HP10×57 | 57 | 84.8 | 10.0 | 10.225 | 0.565 | 0.565 |
| HP12×53 | 53 | 78.9 | 11.8 | 12.045 | 0.435 | 0.435 |
| HP12×63 | 63 | 93.8 | 11.9 | 12.125 | 0.515 | 0.515 |
| HP12×74 | 74 | 110.1 | 12.1 | 12.215 | 0.605 | 0.605 |
| HP14×73 | 73 | 108.6 | 13.6 | 14.585 | 0.505 | 0.505 |
| HP14×89 | 89 | 132.4 | 13.8 | 14.695 | 0.615 | 0.615 |
kg/m values are calculated using 1 lb/ft = 1.48816 kg/m. Nominal dimensions remain subject to applicable production tolerances.
European HP Reference Sizes
European catalogue profiles should be specified separately from American HP designations.
| European HP designation | Catalogue mass (kg/m) | Depth h (mm) | Flange width b (mm) | Web thickness (mm) | Flange thickness (mm) |
|---|---|---|---|---|---|
| HP320×88 | 88.5 | 303 | 304 | 12 | 12 |
| HP320×103 | 103 | 307 | 306 | 14 | 14 |
| HP400×122 | 122 | 348 | 390 | 14 | 14 |
Source: ArcelorMittal HP Catalogue, 2018. Confirm the current producing mill's section table, rolling programme and grade availability.
How to Read HP12×53
HP identifies the bearing-pile family. 12 identifies the nominal depth series in inches. 53 indicates nominal weight in pounds per foot.
The material grade is specified separately. Use the section table for actual nominal dimensions.
HP Section vs. H Beam vs. Sheet Pile
| Product | Main function | Selection distinction |
|---|---|---|
| HP bearing pile | Driven foundations; engineered soldier piles | Dedicated pile profile with relatively substantial web and flanges |
| Structural H / W beam | Beams and columns | Different section proportions; substitution requires design review |
| Steel sheet pile | Interlocking retaining or cutoff walls | Uses interlocks; an HP section alone does not create a continuous watertight wall |
How to Specify H Piles
Provide the approved pile schedule. Include the complete designation and quantity for each profile.
Confirm the material requirement. State grade, standard edition, delivery condition and additional tests.
Define lengths and tolerances. Include initial lengths, extension pieces and cut-end requirements.
Identify connection work. Submit approved splice, pile-shoe, attachment and pile-cap details.
Set inspection and delivery requirements. Specify certificates, inspection hold points, marking and destination port.
Pile capacity must be established for the foundation system. Ground resistance, driving stresses, pile stability, lateral loads and environmental conditions can govern selection. Steel strength or cross-sectional area alone cannot establish a safe working load.
Manufacturing and Processing Options
Hot-rolled HP sections follow a section rolling route, followed by cooling, finishing and inspection. A fabricated H section assembled from welded plates is a separate product route and requires appropriate identification and approval.
Additional processing can be reviewed against project drawings.
| Option | Information required |
|---|---|
| Cut-to-length | Piece lengths, quantities and permitted tolerances |
| End preparation / beveling | End geometry and approved welding detail |
| Holes and attachments | Locations, dimensions, tolerances and design requirements |
| Splice components | Connection design, material grade and inspection requirements |
| Pile shoes | Toe conditions and engineer-approved shoe details |
| Surface preparation / coating | Exposure conditions, coating specification and inspection scope |
Splices and pile shoes are project-specific components. Processing scope is confirmed in the quotation.
Send Your Drawings for a Processing Review
Inspection and Material Documentation
Agree on inspection requirements before production or allocation. Records should match the order and remain traceable to the delivered piles.
| Inspection item | Verification focus |
|---|---|
| Section identification | Profile designation, material grade and producing mill |
| Dimensions | Depth, width, thicknesses, length, straightness and applicable shape tolerances |
| Surface and ends | Surface condition, damage and specified end preparation |
| Material test report | Heat number, chemistry and required mechanical test results |
| Additional tests | Specified impact or other tests, sampling and acceptance criteria |
| Fabricated connections | Welding procedures and examination requirements where included |
| Dispatch records | Piece or bundle identification, packing list and inspection records |
An EN 10204 Type 3.1 inspection certificate may be requested where available from the producing mill and included in the order. Third-party inspection should be specified separately, with an agreed scope and timing. parker.com
Material certification verifies the supplied steel against purchase requirements. Pile load testing and driving records address the installed foundation and are separate from mill certification.
Surface Condition, Corrosion and Packing
Mill-finish material is an ordering option. Coating, galvanizing or other protective work can be reviewed where required by the design.
Corrosion allowances and protection measures depend on the project environment. State requirements for soil, groundwater, marine exposure, aggressive fill or exposed pile lengths rather than assuming a fixed service life.
Packing is planned around pile length, handling equipment and transport mode. Agree on bundle weights, supports, lifting access, identification and loading arrangements before dispatch. Include export-document requirements and any container or break-bulk shipping restrictions in the inquiry.
Typical Applications
Bridge and infrastructure foundations: Driven piles selected through geotechnical and structural design.
Industrial and commercial foundations: Pile systems beneath buildings, plant structures and equipment foundations.
Soldier pile and lagging walls: Engineered excavation-support arrangements.
Temporary works and cofferdam bracing: Members selected for the approved temporary-works design.
Project Supply Support from Dongmeng Group
Dongmeng Group can review section sourcing, drawing-based processing, surface treatment and packing requirements within one project inquiry. A complete specification helps establish the supply route, inspection scope and quotation basis before an order is placed. cndmmetal.com
For comparable quotations, use the same profile, grade, lengths, quantities, certificate requirements and delivery terms. Confirm whether pricing is based on theoretical mass, actual weighed mass or piece quantity.
Frequently Asked Questions
1. Is an HP section the same as an ordinary H beam?
No. HP is a dedicated bearing-pile family. Similar overall dimensions do not establish equivalent web thickness, section properties or compliance with the pile design.
2. What does HP12×53 mean?
It identifies an American HP section in the nominal 12-inch depth series, weighing 53 lb/ft. Actual nominal dimensions come from the section table.
3. Which steel grade should I specify?
Use the project-specified grade. ASTM A572 Grade 50 is a common route. Other ASTM or EN grades require confirmation of section availability and project acceptance.
4. Can S355 replace ASTM A572 Grade 50?
Only after purchaser and engineering approval. Compare the complete material specification, thickness-dependent requirements, toughness, delivery condition and inspection records.
5. How much load can one H pile carry?
There is no universal value. Capacity depends on structural resistance, ground conditions, pile length, installation and the foundation design.
6. Can H piles be spliced?
Yes, where the design permits an approved welded or mechanical splice. Provide connection details, the applicable code and inspection requirements.
7. Does every H pile need a pile shoe?
No. Shoe requirements depend on toe conditions, expected obstructions, driving demands and the approved installation design.
8. Can I request a 3.1 certificate or third-party inspection?
Specify these requirements in the inquiry. Certificate availability is checked with the mill; third-party inspection requires an agreed scope, acceptance criteria and timing.
9. What lengths, MOQ and lead time are available?
These depend on section, grade, quantity, processing and stock or rolling availability. Submit a complete pile schedule for confirmation.
10. Can H piles be used for retaining walls?
They can be used in engineered soldier pile and lagging systems. HP sections have no sheet-pile interlocks and do not independently create a continuous watertight wall.
Request a Steel H Pile Quotation
Send your pile schedule or drawings with:
Profile and material: Complete HP designation, grade and standard edition.
Quantity and lengths: Pieces by length, or tonnage with a length schedule.
Processing: End preparation, splices, pile shoes and coating details.
Inspection: Certificate type, supplementary tests and third-party inspection.
Delivery: Destination port, delivery terms and required shipment date.
Example inquiry:
"HP12×53, ASTM A572 Grade 50, 12 m lengths, 100 pieces, mill test report, no additional processing. Please quote CIF to the specified destination port and confirm availability."
Request a Quote | Send Your Pile Schedule
Office Information
Phone: +86 157 6921 4734
Email: office@dongmjd.com
WhatsApp: +86 157 6921 4734
Address: Room 4107, Runfeng Building, Sanqiao New Street, Weiyang District, Xi'an City, Shaanxi Province, China.
Hot Tags: steel h pile, China steel h pile manufacturers, suppliers, factory